40-7705I-UM Page 38 Rev 4 March 16, 2007
WARNING! AVOID ERROR MESSAGES
Be sure there is a functioning Alarm Automation system properly
attached and in service on the configured port and or IP address,
ready to receive signals immediately after the parameters are
saved. Messages may be generated and any enabled heartbeat
needs to get its proper responses.
Leave the Serial Device Name, Heartbeat Signal frequencies and
IP Address blank, if you need to configure a security Business Unit
to not produce error messages, due to no in service Alarm
Automation System.
Special Instructions:
If this is an additional Business Unit that will use a
Serial Port that has already been assigned and configured, then a Blank
entry MUST be used in the Serial Device Name and Heartbeat Signal
Frequency fields. Instructions in Appendix D must be followed after
completing this Business Unit, to link it to the Business Unit that has a
configured serial port, before it will be able to utilize the Serial Port.
o Serial Port Parameters:
Serial Device Name: Enter the name of the serial device used for
the serial port. Default value is: /dev/ttyS1 for COM1 (upper serial
port). /dev/ttyS0for COM2 is used internally and is not available.
Com Parameters: Select the Baud Rate, Data Bits, Parity, and Stop
Bits to use on the Serial for these alarm automation messages.
Default values are 1200, 7, Odd and 2 Stop Bits. See Appendix E
for a listing of generated messages.
Heartbeat Signal Frequency: Enter the number of seconds between
heartbeat signals on the serial port from Alarm Automation. The
heartbeat is an upper case “S” when in Ademco 685 emulation.
You should add a period of time as a window that the signal may
be sent. Example: If your Alarm Automation sends an “S” every
20 seconds, you may want to set this parameter to 40. This allows
the Alarm Automation an additional widows of 20 seconds and
two attempts to send the heartbeat before a fault message is
generated by the 7705i Receiver. This shall be configured by
UL1981 Central-Station Automation Systems Requirements.
Entering a value of 0 disables the feature and the 7705i will not be
looking for the heartbeat. The MultiNet Receiver will not
annunciate a fault due to no heartbeat being sent.
o IP Parameters:
IP Address: Enter the IP address of the Alarm Automation system.
The default is blank and should only have an entry if there is to be
communication to Alarm Automation via TCP/IP.
Port Number: is the IP port that the 7705i send it alarm automation
messages on. Default is blank.